description: "Teaches load and performance testing from zero: how to choose between k6, JMeter, Gatling, Locust, and Artillery based on observable project facts (team language, tests-as-code vs GUI authoring, protocols beyond HTTP, CI gating needs); the six load profiles (smoke, average-load, stress, spike, soak, breakpoint) and the question each one answers; the difference between open workload models that hold arrival rate constant and closed models that hold concurrent users constant; why percentiles rather than averages are the unit of measurement; and how to turn a run into a pass/fail CI gate, with a first runnable k6 script. Use when a service needs performance coverage and the tool, the load profile, or the pass/fail threshold has not been decided yet."
---
# load-testing-overview
Load testing drives concurrent, sustained traffic at a deployed system and
measures what happens to response time, throughput, and errors while that
traffic runs. It assumes correctness and asks whether the system stays fast and
correct under load, and where it stops being either. It needs a deployed
environment, realistic data volumes, and a real network path; run one against a
laptop dev server and you measured the laptop.
## Pick a tool from what is already in the repo
Five tools cover almost every case. Read the table top to bottom and stop at the
first row that is true of your project. The rows are ordered so that hard
constraints (protocol, who authors the tests) beat preferences (language).
| Observable fact about your project | Pick | Why |
|---|---|---|
| You must generate load over JDBC, JMS, LDAP, FTP, SMTP/POP3/IMAP, TCP, or raw shell commands, not only HTTP | **JMeter** | It is the only one of the five with those built in: JMeter lists Web HTTP/HTTPS, "SOAP / REST Webservices", FTP, "Database via JDBC", LDAP, "Message-oriented middleware (MOM) via JMS", "Mail - SMTP(S), POP3(S) and IMAP(S)", "Native commands or shell scripts", and TCP ([JMeter home](https://jmeter.apache.org/)) |
| Non-programmers (manual QA, ops) must build and maintain the tests themselves | **JMeter** | It is "a 100% pure Java application" with a "Full featured Test IDE" GUI for recording and building plans ([JMeter home](https://jmeter.apache.org/)) |
| The team's build is Maven, Gradle, or sbt and the testers are JVM developers | **Gatling** | "Since 3.7, Gatling supports writing tests in Java, Scala, and Kotlin" and installs through those build tools ([Gatling install](https://docs.gatling.io/reference/deploy/install-local/)) |
| The test logic needs arbitrary Python (an internal SDK, pandas, a crypto lib) | **Locust** | Tests are plain Python: `from locust import HttpUser, task` in a `locustfile.py` ([Locust quickstart](https://docs.locust.io/en/stable/quickstart.html)) |
| You want the load profile declared as data, not code, and Node is already installed | **Artillery** | The test script is YAML: `config.phases` "defines how Artillery generates new virtual users (VUs) in a specified time period" ([Artillery test script](https://www.artillery.io/docs/reference/test-script)) |
| Anything else: HTTP/gRPC/WebSocket service, JS or TS team, tests must live in git | **k6** | Scripts are JavaScript, the runner is a single binary, and it natively supports HTTP/1.1, HTTP/2, WebSockets, and gRPC ([k6 protocols](https://grafana.com/docs/k6/latest/using-k6/protocols/)) |
Two follow-on constraints that change the answer:
- **Tests must be reviewable in a pull request.** k6, Gatling, Locust, and
Artillery all store tests as ordinary source files. JMeter plans are `.jmx`
files produced by the GUI and passed to the runner with
`jmeter -n -t my_test.jmx -l log.jtl` ([JMeter get started](https://jmeter.apache.org/usermanual/get-started.html)).
Teams commonly find those generated plan files hard to diff in review; that is
a practitioner observation, not a documented limitation. If code review of the
test itself matters to you, that alone rules JMeter out.
- **CI must fail the build with no extra plumbing.** k6 and Artillery both exit
non-zero on a failed budget out of the box (see the threshold section below).
With JMeter you get a `.jtl` results file and have to assert on it yourself.
**If you truly have no constraint, choose k6.** It has the shortest path from
zero to a failing build, which is the only path that matters at the start.
## The six load profiles
Newcomers say "load test" for all six of these and then argue past each other.
Each name answers a different question, and the profiles are defined by k6 as
follows ([k6 test types](https://grafana.com/docs/k6/latest/testing-guides/test-types/)):
| Profile | Question it answers | Shape |
|---|---|---|
| **Smoke** | Does the script itself work, and is the system sane at trivial load? | Low VUs, seconds to a couple of minutes |
| **Average-load** | How does the system behave under expected normal conditions? | Average production VUs, 5 to 60 minutes |
| **Stress** | What happens when demand exceeds the expected average? | VUs above average, 5 to 60 minutes |
| **Spike** | Does the system survive a sudden, short, massive surge? | Very high VUs, a few minutes |
| **Soak (endurance)** | Is it still reliable after hours of continuous operation? | Average VUs, hours |
| **Breakpoint** | Where is the capacity ceiling? | Ramp up incrementally until it breaks |
Two of these are routinely confused. **Stress** holds an above-average load
steady and watches how the system copes; **breakpoint** keeps increasing load
until the system fails, so its output is a number (the ceiling), not a verdict.
**Soak** uses ordinary load and long duration on purpose: it exists to catch
memory leaks, connection-pool exhaustion, and log-disk growth, which a 10-minute
run cannot see.
Run smoke first, always. A broken script under 300 VUs produces a very
convincing graph of nothing.
## Open vs closed workload models
This is the single most misunderstood idea in the field, and it decides whether
your numbers mean anything.
- **Closed model:** you hold the number of concurrent users constant. New work
starts only when old work finishes. In k6's words, "In the closed model, VU
iterations start only when the last iteration finishes," so "the target
system's response time can influence the throughput of the test"
([k6 open vs closed](https://grafana.com/docs/k6/latest/using-k6/scenarios/concepts/open-vs-closed/)).
- **Open model:** you hold the arrival rate constant. "In the open model, on the
other hand, VUs arrive independently of iteration completion," so "the response
times of the target system no longer influence the load on the target system"
([k6 open vs closed](https://grafana.com/docs/k6/latest/using-k6/scenarios/concepts/open-vs-closed/)).
Why it matters: under a closed model, when the system slows down, your test
automatically applies *less* load, which hides the problem exactly when it
starts. k6 names this: "In some testing literature, this problem is known as
coordinated omission"
([k6 open vs closed](https://grafana.com/docs/k6/latest/using-k6/scenarios/concepts/open-vs-closed/)).
Real user traffic on a public web service is open (people keep arriving whether
or not you are coping); Gatling frames it the same way, noting open systems
"have no control over the number of concurrent users" while closed systems cap
that number
([Gatling workload models](https://docs.gatling.io/testing-concepts/workload-models/)).
Closed is the right model for a fixed-size worker pool, a call-centre queue, or a
system behind a hard concurrency limit.
For how each tool names its open and closed executors, and the Gatling
"users means open, not closed" trap spelled out, see
[references/tool-executors.md](references/tool-executors.md).
## Run your first test with k6
Install ([k6 install](https://grafana.com/docs/k6/latest/set-up/install-k6/)):
```bash
brew install k6 # macOS
choco install k6 # Windows, Chocolatey
winget install k6 --source winget # Windows, winget
docker pull grafana/k6 # any platform
```
Write `script.js`:
```javascript
import http from 'k6/http';
import { check, sleep } from 'k6';
export const options = {
vus: 10,
duration: '30s',
thresholds: {
http_req_duration: ['p(95)<500'], // 95th percentile under 500ms
http_req_failed: ['rate<0.01'], // under 1% failed requests
},
};
export default function () {
const res = http.get('https://your-service.example.com/health');
check(res, { 'status 200': (r) => r.status === 200 });
sleep(1);
}
```
Run it ([k6 running](https://grafana.com/docs/k6/latest/get-started/running-k6/)):
```bash
k6 run script.js
k6 run --vus 10 --duration 30s script.js # same shape, set from the CLI
```
**What success looks like:** a live progress table during the run, then an
end-of-run summary in which every threshold line is marked with a green check.
`http_req_duration` reports `avg`, `min`, `med`, `max`, `p(90)`, and `p(95)`
([k6 metrics](https://grafana.com/docs/k6/latest/using-k6/metrics/)). If any
threshold fails, "the little green checkmark next to the threshold name would be
a red cross and k6 would exit with a non-zero exit code"
([k6 thresholds](https://grafana.com/docs/k6/latest/using-k6/thresholds/)). That
non-zero exit is your entire CI gate: no plugin, no parser, no dashboard.
That first run is a smoke test. Only after it is green should you raise VUs or
switch to an arrival-rate executor.
## Percentiles, not averages
Report and gate on percentiles. An average response time is a single number
produced by summing everything and dividing, so a handful of 8-second requests
disappear into thousands of 40ms ones. The p95 and p99 are the response times
that 5% and 1% of requests exceeded, which is the experience of your slowest
users and, on a page that makes 20 backend calls, the experience of most
sessions.
This is why every tool in the list exposes percentiles as first-class threshold
targets: k6 with `http_req_duration: ['p(95)<200']`
([k6 thresholds](https://grafana.com/docs/k6/latest/using-k6/thresholds/)) and
Artillery with `p95: 200` in its `ensure` block
([Artillery ensure](https://www.artillery.io/docs/reference/extensions/ensure/)).
Practical rules, which are practitioner convention rather than a documented
standard:
- Quote p50, p95, and p99 together. p50 alone flatters you; p99 alone is noisy
at low request counts, and a p99 over 200 requests is two data points.
- Never average percentiles across separate runs or separate load generators.
The result is not a percentile of anything.
- Compare like with like: same profile, same duration, same environment. A p95
from a 30-second smoke run is not comparable to one from a two-hour soak.
## A test without a threshold is just a graph
If a run cannot fail, nobody will ever act on it. Define the pass/fail budget
before the run, and derive the numbers from your service level objectives, not
from whatever the first run happened to produce.
k6 states this directly: "Thresholds are the pass/fail criteria that you define
for your test metrics. If the performance of the system under test (SUT) does not
meet the conditions of your threshold, the test finishes with a failed status"
([k6 thresholds](https://grafana.com/docs/k6/latest/using-k6/thresholds/)). Set
`abortOnFail` on a threshold to stop the run the moment the condition goes false
instead of burning the full duration
([k6 thresholds](https://grafana.com/docs/k6/latest/using-k6/thresholds/)).
Artillery's `ensure` extension is the same idea in YAML: "Artillery can validate
if a metric's value meets a predefined threshold. If it doesn't, it will exit
with a non-zero exit code"
([Artillery ensure](https://www.artillery.io/docs/reference/extensions/ensure/)).
The k6 guidance on where to run these is worth taking seriously: "As a general
rule on pre-release environments, we should run our larger tests with quality
gates, Pass/Fail criteria that validate SLOs or reliability goals," but "Unless
your verification process is mature, do not rely entirely on Pass/Fail results to
guarantee the reliability of releases"
([k6 automated performance testing](https://grafana.com/docs/k6/latest/testing-guides/automated-performance-testing/)).
Gate the short smoke and average-load runs in CI; run stress, spike, soak, and
breakpoint on a schedule against a dedicated environment.
## Traps that catch newcomers first
The seven mistakes that most often invalidate a first effort - load testing the
generator itself, running JMeter's GUI as the generator, one URL / one account,
presenting a closed-model VU count as capacity, skipping warm-up, extrapolating
from a scaled-down environment, and recording latency without error rate - are
detailed with citations in [references/traps.md](references/traps.md).
## Related skills
Optional deeper dives, if you have them installed:
`k6-load-testing`,
`gatling-load-testing`,
`jmeter-load-testing`,
`locust-load-testing`,
`latency-percentile-analyzer`.