name: neqsim-process-safety
version: "1.5.0"
description: "Process safety methodology — barrier management, PSFs/SCEs, HAZOP guidewords, LOPA worksheets, SIL determination per IEC 61511, integrated facility safety response, safety change revalidation, independent benchmarks, bow-tie analysis, risk-matrix scoring, TR3001 overpressure-protection studies, and trapped-liquid fire rupture screening. USE WHEN: a task requires barrier registers, hazard identification, layer-of-protection analysis, safety-integrity-level assignment for an SIF, integrated ESD/compressor-trip/blowdown/relief/flare evidence, safety-study revalidation after change, independent method benchmarks, overpressure relief-cause / governing-case studies, trapped liquid rupture/PFP demand, or quantitative risk evaluation. Anchors on neqsim.process.safety.barrier, neqsim.process.safety.risk, neqsim.process.safety.overpressure, and neqsim.process.safety.rupture classes."
last_verified: "2026-07-18"
requires:
  java_packages: [neqsim.process.safety.barrier, neqsim.process.safety.risk, neqsim.process.safety.overpressure, neqsim.process.safety.rupture, neqsim.process.safety.risk.sis.nog070, neqsim.process.safety.esd, neqsim.process.safety.api14c, neqsim.process.safety.compliance]
---

# NeqSim Process Safety Skill

Systematic hazard identification, layer-of-protection analysis (LOPA), and
safety-integrity-level (SIL) determination — the quantitative half of process
safety that complements depressurization (`neqsim-dynamic-simulation`) and relief
sizing (`neqsim-relief-flare-network`).

## When to Use

- HAZOP / HAZID node walkdown with deviation guidewords
- Barrier management for PSFs/SCEs with document evidence and performance standards
- LOPA for a specific scenario — calculate residual frequency and required RRF
- SIL determination for an SIF — IEC 61508 / IEC 61511 verification
- Closed-loop SIF execution from live process signal through MooN voting and final element
- Bow-tie analysis (top event with threats + barriers + consequences)
- ALARP / risk-matrix scoring (5×5)
- Trapped-liquid fire rupture screening for blocked-in liquid-filled segments,
  including PFP demand and source-term handoff
- Overpressure-protection study for a protected item — enumerate credible relief
  contingencies, select the governing case, size the PSV, and check TR3001 / API
  521 compliance

Standards: **IEC 61508**, **IEC 61511**, **CCPS LOPA Guidelines**, **API 521 / ISO 23251**, **API 520**, **TR3001**, **ASME VIII Div 1 (UG-125)**, **ASME B31.3/B31.4**, **ASME B16.5**, **API 754**, **NORSOK Z-013**.

## Method 0b — Trapped-Liquid Fire Rupture Screening

Load `neqsim-trapped-liquid-fire-rupture` when a safety study concerns a
blocked-in liquid-filled pipe segment exposed to fire, no pressure relief, PFP
endurance, flange/pipe rupture, or a Word/HTML study report based on P&IDs/STID,
line lists, material certificates, and fire documents.

Recommended sequence:

1. Retrieve the evidence package with `neqsim-stid-retriever`: P&ID/STID,
   line list, piping spec, material certificate, flange/bolt/gasket data,
   fire-zone/PFP documents, relief basis, and design basis.
2. Extract a structured segment list with `neqsim-technical-document-reading`:
   isolation boundary, line numbers, fluid, P/T, ID, wall thickness, length,
   material grade, flange class, fire basis, PFP endurance, relief availability,
   acceptance criteria, and evidence gaps.
3. Use `TrappedInventoryCalculator` to calculate trapped mass and volume.
4. Use `FireExposureScenario`, `MaterialStrengthCurve`, and
   `TrappedLiquidFireRuptureStudy` to calculate event times and limiting mode.
5. Convert outputs to `SafetySystemDemand` for PFP checks and to
   `SourceTermResult` for consequence handoff if rupture is predicted.
6. Report all screening defaults as assumptions. Missing project data must stay
   visible in an evidence/gaps register.

## Method 0 — Evidence-Linked Barrier Register

Use `BarrierRegister`, `SafetyCriticalElement`, `SafetyBarrier`, `PerformanceStandard`,
and `DocumentEvidence` when agents read technical documentation and need a traceable
handoff into LOPA, SIL, bow-tie, or QRA.

Recommended sequence:

1. Extract `DocumentEvidence` from P&IDs, C&E charts, SRS, SIL verification reports,
   inspection reports, vendor datasheets, and operating procedures.
2. Build `PerformanceStandard` objects for each PSF/SIF/SCE function with target PFD,
   availability, proof-test interval, response time, and acceptance criteria.
3. Build `SafetyBarrier` objects with type, status, PFD/effectiveness, equipment tags,
   hazard ids, owner, evidence, and performance-standard links.
4. Group barriers under `SafetyCriticalElement` records using process equipment tags.
5. Run MCP `runBarrierRegister` to get validation findings plus `lopaHandoff`,
   `silHandoff`, `bowTieHandoff`, and `qraHandoff` blocks.

Credit rule: do not claim LOPA credit unless the barrier is `AVAILABLE`, has a valid
PFD, has a linked performance standard, and has traceable evidence. Missing evidence
must remain visible as a validation finding.

## Method 1 — HAZOP Guidewords

Apply the 7 standard guidewords to each design intent at every node:

| Guideword | Deviation example                         | Typical cause                       |
| --------- | ----------------------------------------- | ----------------------------------- |
| NO        | No flow to separator                      | Pump trip, blocked inlet            |
| MORE      | More pressure in V-100                    | PCV stuck open, inlet surge         |
| LESS      | Less level in V-100                       | LCV stuck open, drain leak          |
| AS WELL AS | Water carryover in gas                   | Demister flooding, wave action      |
| PART OF   | Wrong composition fed                     | Crossover from neighbouring train   |
| REVERSE   | Reverse flow from compressor              | Check valve failure                 |
| OTHER THAN | Maintenance with line live               | Procedural / isolation failure      |

Output as a HAZOP worksheet table; each row → candidate LOPA scenario.

For automated studies from STID/P&ID documents and NeqSim process simulations,
use MCP `runHAZOP`. It accepts a standard `runProcess` JSON model plus optional
document-extracted nodes, safeguards, evidence references, selected failure
modes, and a `barrierRegister`. The runner executes generated safety scenarios
on copied `ProcessSystem` models and returns IEC 61882 rows, simulation evidence,
quality gates, barrier-register handoff, and report markdown. See
`docs/safety/automated_hazop_from_stid.md`.

For a P&ID Safety Analyser / AI-HAZOP front-end that quantifies one deviation at
a time, use MCP `runHazopScenario` (backed by
`neqsim.mcp.runners.HazopScenarioRunner`). It accepts a `runProcess` JSON model
plus an optional `guideWord` / `parameter` / `nodeTag` filter and a `limits`
policy, and returns a stable `schemaVersion "1.0"` response where every finding
carries a `computedValue`, `designLimit`, `verdict` (PASS / EXCEEDS /
NOT_EVALUATED), `standardReference`, and a `limitBasis` provenance string
(`HazopConsequenceFinding#getLimitBasis()`) so a reviewer can see whether the
limit is a data-sheet value or a screening default. Equipment design limits
(`neqsim.process.mechanicaldesign.DesignConditions`) round-trip into DEXPI as a
`GenericAttributes Set="DesignConditions"` group, and blocked-outlet MORE
PRESSURE deviations can be screened with
`neqsim.process.safety.depressurization.BlockedOutletOverpressureAnalyzer`. See
`docs/safety/ai_hazop_input_format.md` for the full input-data format.

## Method 2 — LOPA Worksheet

Use [`LOPAResult`](../../../src/main/java/neqsim/process/safety/risk/sis/LOPAResult.java) to compute residual frequency:

```java
import neqsim.process.safety.risk.sis.LOPAResult;

LOPAResult lopa = new LOPAResult();
lopa.setScenarioName("V-100 overpressure during compressor surge");
lopa.setInitiatingEventFrequency(0.1);   // /yr — surge event
lopa.setTargetFrequency(1.0e-5);         // /yr — tolerable for safety SIF

// Independent Protection Layers (each must be IEC 61511 IPL-eligible)
lopa.addLayer("BPCS pressure control",     0.10, 0.1,    0.01);
lopa.addLayer("Operator response (alarm)", 0.10, 0.01,   0.001);
lopa.addLayer("PSV @ design",              0.01, 0.001,  1.0e-5);

System.out.println(lopa.toVisualization());
System.out.println("Target met? " + lopa.isTargetMet());
System.out.println("Required additional SIL: " + lopa.getRequiredAdditionalSIL());
```

**IPL eligibility rules (IEC 61511):**
- Independent of initiating event and other IPLs
- Specific (one task, one mode)
- Auditable (testable, with proof-test interval)
- BPCS counts as one IPL only (typically PFD = 0.1)

### Method 2b — Traceable HAZOP/LOPA to draft SRS

Use `LopaScenarioDefinition`, `ProtectionLayerDefinition`, and `HazopLopaSrsWorkflow` when an
approved HAZOP row and user-supplied risk basis need a machine-readable handoff into SRS drafting.
The workflow credits a layer only when independence from the initiating event and other layers,
specificity, auditability, proof-test/inspection interval, and a controlled evidence reference are
all declared. Ineligible safeguards remain visible but receive no frequency reduction.

If a risk gap remains, the result creates a `SafetyRequirementSpecificationDraft` carrying the
HAZOP node/deviation, LOPA reference, SIF tag, trip, safe state, response time, voting, proof-test,
reset, and bypass requirements. The draft is always `REVIEW_REQUIRED` and never fit for construction.
No draft is created when credited existing layers meet the supplied target.

After accountable HAZOP, LOPA, and SRS approval, hand the approved inputs to
`SafetyFunctionDesign`, reliability/degraded-mode assessment, and closed-loop transient
verification. See `docs/process/safety/hazop-lopa-srs-handoff.md`.

## Method 3 — SIL Determination

After LOPA tells you a SIL is needed, verify with [`SafetyInstrumentedFunction`](../../../src/main/java/neqsim/process/safety/risk/sis/SafetyInstrumentedFunction.java):

```java
import neqsim.process.safety.risk.sis.SafetyInstrumentedFunction;
import neqsim.process.safety.risk.sis.SafetyInstrumentedFunction.SIFCategory;

SafetyInstrumentedFunction sif = SafetyInstrumentedFunction.builder()
    .id("SIF-001")
    .name("HIPPS on V-100")
    .description("Close XV-1001A/B on PT-1001 high-high (2oo3)")
    .sil(2)                           // claimed
    .pfd(5.0e-3)                      // PFD_avg from supplier verification
    .testIntervalHours(8760.0)        // 1-year proof test
    .mttr(8.0)
    .architecture("2oo3")
    .category(SIFCategory.HIPPS)
    .initiatingEvent("Compressor surge → backflow")
    .safeState("XV closed, V-100 isolated")
    .build();

double rrf = sif.getRiskReductionFactor();    // 1/PFD
int silAchieved = sif.getSil();
```

**SIL bands (IEC 61508):**

| SIL | PFDavg              | RRF             |
| --- | ------------------- | --------------- |
| 1   | 1e-2 to 1e-1        | 10–100          |
| 2   | 1e-3 to 1e-2        | 100–1000        |
| 3   | 1e-4 to 1e-3        | 1000–10000      |
| 4   | 1e-5 to 1e-4        | 10000–100000    |

### Method 3b — NOG 070 SIL Catalogue (Norwegian shelf typical SIFs)

For Norwegian-shelf projects, the NOG 070 (070 Norsk olje og gass) guideline
gives **pre-determined minimum SIL** for typical SIFs — use
`Nog070SilCatalogue` / `Nog070SilDetermination` to look up the minimum and
verify the achieved SIL from PFD:

```java
import neqsim.process.safety.risk.sis.nog070.Nog070SifType;
import neqsim.process.safety.risk.sis.nog070.Nog070SilDetermination;

// HIPPS minimum is SIL 3; PFD 1e-4 achieves SIL 3 → compliant
Nog070SilDetermination r =
    Nog070SilDetermination.evaluate(Nog070SifType.HIPPS_PIPELINE, 1.0e-4);
int achieved = r.getAchievedSil();   // 3
int minimum  = r.getMinimumSil();    // 3
boolean ok   = r.isCompliant();      // true
String json  = r.toJson();
```

`Nog070SifType` includes `HIPPS_PIPELINE`, `ESD_SUBSEA_ISOLATION` (SIL 3),
`BLOWDOWN_HYDROCARBON_SEGMENT`, `PSD_PROCESS_SEGMENT` (SIL 2), and `CUSTOM`
(supply an explicit minimum via the 3-arg `evaluate`). Verified by
`Nog070SilCatalogueTest`.

### Method 3c — ESD Response-Time Budget (NOG 070 / IEC 61511)

Verify the full detection → logic → final-element chain fits the allowable ESD
response time with `EsdResponseTimeSimulator`:

```java
import neqsim.process.safety.esd.EsdResponseTimeSimulator;
import neqsim.process.safety.esd.EsdResponseTimeSimulator.EsdResponseTimeResult;

EsdResponseTimeResult res = new EsdResponseTimeSimulator()
    .setSifTag("ESD-1234")
    .addDetection("PT-1001 high-pressure", 1.0)         // [s]
    .addLogic("Logic solver scan + 2oo3 vote", 0.5)     // [s]
    .addValve("ESDV-2001", 0.5, 8.0)                    // command delay + stroke [s]
    .setAllowableResponseTimeS(15.0)
    .evaluate();

double total = res.getTotalResponseTimeS();   // 10.0
double margin = res.getMarginS();             // 5.0
boolean within = res.isWithinBudget();        // true
```

Verified by `EsdResponseTimeSimulatorTest`.

### Method 3d — Closed-loop SIF transient verification

Use `ClosedLoopSafetyFunction` inside a `DynamicSafetyScenario` when a response-time budget must
be demonstrated against the process model rather than summed from prepared durations. Bind every
`SafetyFunctionChannel` to the isolated process copy, select the SRS voting pattern, then pass an
existing `ESDLogic`, `HIPPSLogic`, or other `ProcessLogic` as the final-element sequence.

Recommended sequence:

1. Configure and solve the normal process case.
2. Apply one controlled initiating event on the scenario copy.
3. Bind sensor channels to live process properties, including response delay and an explicit
   `FaultMode` for degraded cases.
4. Use the SRS MooN `VotingPattern` and logic-solver delay.
5. Define dynamic criteria for the actual safe state and deadline, such as ESD valve opening,
   protected pressure, compressor state, or depressuring pressure.
6. Review `DynamicSafetyScenarioResult.getLogicEvidence()` for readings, bypass/fault state, vote
   time, final-element actuation, and trace; do not approve from the boolean verdict alone.

See `docs/process/safety/closed-loop-sif-verification.md`. This simulation evidence does not infer
SIL or approve the SRS; hand the result to the SIL/LOPA and engineering-approval workflow.

### Method 3e — Reliability uncertainty and degraded/maintenance modes

After the deterministic `SafetyFunctionDesign` screen, use `SafetyFunctionReliabilityStudy` to
propagate evidence-based failure-rate, diagnostic-coverage, proof-test, repair-time, beta, and bypass
uncertainty. Always provide a fixed seed and retain P10/P50/P90 PFDavg/PFH, target-met probability,
iteration count, distributions, and their data sources in the verification package.

Use `SafetyFunctionOperatingMode` plus `SafetyFunctionDegradedModeAssessment` before evaluating a
bypass or maintenance state. Record every unavailable, forced-trip, or under-repair channel, actual
proof-test age, authorization reference, compensating measure, elapsed duration, and maximum duration.
The effective architecture (for example 2oo3 to 2oo2) is a demand-capability screen, not permission to
preserve the SIL claim or continue operation.

Handoff the assessed mode back to the closed-loop scenario workflow to verify the physical safe state.
See `docs/process/safety/sif-reliability-and-degraded-modes.md`.

### Method 3f — Integrated facility safety response

Use `FacilitySafetyResponseStudy` after the individual engines have executed when one review package
must join closed-loop ESD/HIPPS evidence, compressor anti-surge trip demand and observed response,
PSV/concurrency results, transient blowdown/flare results, and controlled process limits such as MDMT
or hydrate margin. Supply the actual `DynamicSafetyScenarioResult` and
`CoupledReliefBlowdownFlareResult`; the facility study embeds their maps and must not duplicate their
physics.

Capture compressor response with `CompressorTripResponse.capture(...)`. `AntiSurge.shouldTrip()` is
the demand signal; separately record whether the trip was observed, its response time, allowable
deadline, and evidence reference. Add each minimum or maximum with `ProcessSafetyConstraint` and a
controlled source reference.

Treat `isTechnicallyAcceptable()`, `isEvidenceComplete()`, and `isReadyForEngineeringReview()` as
review gates, never approval. Inspect `getFindings()` and embedded engine results, then obtain the
accountable process-safety, rotating-equipment, flare, piping, and mechanical approvals. See
`docs/process/safety/integrated-facility-safety-response.md`.

### Method 3g — Safety change impact and revalidation

Use `SafetyStudyRevalidationPlanner` with the canonical `EngineeringGraph` and a controlled
`ModelChangeEvent`. Tag safety lifecycle nodes with the `safetyStudyType` property and an accepted
type: `HAZOP`, `LOPA`, `SRS`, `SIF_RELIABILITY`, `SIF_DYNAMIC_VERIFICATION`,
`RELIEF_BLOWDOWN_FLARE`, or `FACILITY_RESPONSE`. Express dependencies with normal graph edges; do not
create a separate safety dependency register.

The planner delegates propagation to `GeneralizedImpactAnalyzer`, then adds type-specific work,
propagation paths, reason edges, stale approvals, unresolved subjects, and cycle findings. Every task
starts incomplete. Close it and restore approval through project MOC/document control.

### Method 3h — Independent safety verification benchmarks

Use `SafetyVerificationBenchmarkSuite` to qualify the versioned SIF PFDavg, LOPA residual-frequency,
and dynamic-response methods against externally supplied values. Declare the source class, controlled
reference, dataset revision, tolerances, and independent-review record. A
`REGRESSION_BASELINE` is useful but deliberately cannot qualify as independent evidence.

Do not call an expected value independent merely because it was entered by a different user. Verify
the calculation or published/vendor/CAE source, assumptions, units, method version, and review record
outside the code. A passing suite qualifies the controlled implementation/case set, not the project
design or SIL target. See `docs/process/safety/safety-change-revalidation-and-benchmarks.md`.

## Method 4 — Bow-Tie Analysis

Use [`BowTieModel`](../../../src/main/java/neqsim/process/safety/risk/bowtie/BowTieModel.java)
+ [`BowTieAnalyzer`](../../../src/main/java/neqsim/process/safety/risk/bowtie/BowTieAnalyzer.java):

```java
import neqsim.process.safety.risk.bowtie.BowTieModel;
import neqsim.process.safety.risk.bowtie.BowTieModel.Threat;
import neqsim.process.safety.risk.bowtie.BowTieAnalyzer;

BowTieModel bt = new BowTieModel("Loss of containment — V-100 gas phase");
bt.addThreat(new Threat("Overpressure", 0.1));
bt.addThreat(new Threat("Corrosion-induced rupture", 0.01));
// preventive barriers reduce threat → top-event frequency
// mitigative barriers reduce consequence severity

BowTieAnalyzer analyzer = new BowTieAnalyzer(bt);
double topEventFreq = analyzer.calculateTopEventFrequency();
```

Export to SVG with `BowTieSvgExporter` for the report.

## Method 5 — 5×5 Risk Matrix

Use [`RiskMatrix`](../../../src/main/java/neqsim/process/safety/risk/RiskMatrix.java) to score and rank scenarios per ISO 31000 / NORSOK Z-013.
Frequencies × Consequence categories → ALARP / intolerable / broadly acceptable bands.

## Method 6 — API RP 14C SAFE Chart (offshore device coverage)

Auto-enumerate process equipment and check that each has its API RP 14C–required
protective devices (PSH/PSL/LSH/LSL/PSV …) with `Api14cSafeChartBuilder`:

```java
import java.util.EnumSet;
import neqsim.process.safety.api14c.Api14cSafeChartBuilder;
import neqsim.process.safety.api14c.Api14cDeviceType;

// declarePresent(...) lists the devices actually installed, then build(process)
Api14cSafeChartBuilder chart = new Api14cSafeChartBuilder()
    .declarePresent("HP separator",
        EnumSet.of(Api14cDeviceType.PSH, Api14cDeviceType.PSV))
    .build(process);

boolean complete = chart.isComplete();   // false → missing devices
chart.getGaps();                         // equipment with missing required devices
String md = chart.toMarkdown();          // SAFE chart table
String json = chart.toJson();
```

`buildAssumingComplete(process)` enumerates equipment and assumes full coverage
(useful for generating the SAFE chart skeleton). Equipment categories come from
`Api14cEquipmentCategory` (e.g. `PRESSURE_VESSEL`). Verified by
`Api14cSafeChartBuilderTest`.

## Method 7 — NORSOK P-002 Process Design Compliance

Screen flare/blowdown/vent hydraulics and drainage against NORSOK P-002 limits
with `NorsokP002ComplianceChecker` (fluent, aggregates all findings):

```java
import neqsim.process.safety.compliance.NorsokP002ComplianceChecker;

NorsokP002ComplianceChecker c = new NorsokP002ComplianceChecker()
    .checkFlareLineMach("Header", 0.5)             // ≤ 0.7 Mach
    .checkBlowdownRhoV2("BDV-1", 150000.0)         // ρv² limit [Pa]
    .checkVentGasVelocity("Vent", 45.0)
    .checkLiquidCarryOver("V-100", 1.0e-4)
    .checkErosionalVelocity("Line-200", 80000.0)
    .recordDepressurisationValve("BDV-2", true, "Sized for fire case")
    .recordDrainSlope("CD-1", true, "1:100 slope OK");

boolean compliant = c.isCompliant();
int failures = c.countNonCompliant();
String json = c.toJson();      // findings tagged e.g. "FLARE_LINE_MACH_07"
```

Verified by `NorsokP002ComplianceCheckerTest`.

## Method 8 — STS-0131 Technical Safety Gate

Aggregate the project safety acceptance checks (PSV margin, MDMT, SIL, custom)
into a single pass/fail gate with `Sts0131Gate`:

```java
import neqsim.process.safety.compliance.Sts0131Gate;
import neqsim.process.safety.risk.sis.nog070.Nog070SifType;
import neqsim.process.safety.risk.sis.nog070.Nog070SilDetermination;

Sts0131Gate gate = new Sts0131Gate();
gate.addPsvSizingMargin(1.0, 1.15, 0.10);   // required, available, minMargin
gate.addMdmt(-20.0, -29.0);                 // operating MDMT vs design min
gate.addSil(Nog070SilDetermination.evaluate(Nog070SifType.PSD_PROCESS_SEGMENT, 5.0e-3));
gate.addCustom("Fire case", true, "Heat input within API 521 envelope");

boolean acceptable = gate.isAcceptable();
int failures = gate.countFailures();
String json = gate.toJson();
```

Verified by `Sts0131GateTest`.

## Method 9 — Overpressure-Protection Study (TR3001 / API 521)

Use `neqsim.process.safety.overpressure` for a structured overpressure study on a
protected item: each cause calculator is fluent and returns an immutable
`ReliefScenario`; the engine picks the maximum-rate **credible** scenario, sizes
the PSV (vapour / liquid / two-phase), and checks acceptance against the ASME
VIII Div 1 accumulation limits (1.10 single non-fire, 1.16 multiple, 1.21 fire).

```java
import neqsim.process.safety.overpressure.*;

// 1. Cause scenarios (fluent → ReliefScenario)
ReliefScenario blocked = new BlockedOutletRelief().setName("Blocked gas outlet")
    .setInflowRateKgPerHr(36000.0).setReliefPressureBara(50.0)
    .setReliefTemperatureC(20.0).setFluid(gas).calculate();
ReliefScenario fire = new FireCaseRelief().setName("Pool fire")
    .setVesselDiameterM(2.0).setWettedHeightM(3.0)     // or setWettedAreaM2(..)
    .setHasDrainage(true).setHasFireFighting(true)
    .setLatentHeatJPerKg(350000.0).setReliefPressureBara(60.0)
    .setReliefTemperatureC(120.0).setFluid(gas).calculate();

// 2. Engine: governing case + sizing + acceptance
ProtectedItem item = new ProtectedItem("V-100", 100.0)   // tag, MAWP [bara]
    .setReliefSetPressureBara(100.0).setBackPressureBara(1.5);
OverpressureStudyResult result = new OverpressureProtectionStudy(item)
    .addScenario(blocked).addScenario(fire).evaluate();

result.getGoverningScenario().getName();   // worst credible case
result.getRequiredAreaIn2();               // API 526 required orifice area
result.getRecommendedOrifice();            // orifice letter
result.isCapacityAdequate();               // area-based adequacy
result.getAcceptance().getAccumulationFraction();

// 3. TR3001 compliance findings (PASS / FAIL / NEEDS_REVIEW)
List<ComplianceFinding> findings = new TR3001ComplianceChecker().check(result);
boolean compliant = new TR3001ComplianceChecker().isCompliant(findings);

// 4. Disposal-header roll-up (API 521 §5.3)
ReliefDisposalResult disposal = new ReliefDisposalNetwork("Fire zone 1")
    .addRelief(resultA, true).addRelief(resultB, true).calculate();
disposal.getTotalSimultaneousKgPerS();
disposal.getPeakSingleKgPerS();
disposal.getGoverningContributor();
```

- Cause calculators: `BlockedOutletRelief`, `CheckValveLeakRelief`,
  `ControlValveFailureRelief`, `TubeRuptureRelief`, `FireCaseRelief`.
- Mark double-jeopardy cases non-credible with `.credible(false)` to exclude
  them from governing-case selection.
- `TR3001ComplianceChecker` emits six findings: credible scenarios (SR-26500),
  governing case (SR-26503), capacity (SR-26506), acceptance (SR-26510), fire
  basis (SR-26504), and dynamic determination (SR-26565); `isCompliant` is false
  if any finding is `FAIL`.
- Set `ReliefScenario` phase to `LIQUID` (`densityKgPerM3`/`viscosityPaS`) or
  `TWO_PHASE` (`gasMassFraction`, `gasDensityKgPerM3`, `liquidDensityKgPerM3`,
  `latentHeatJPerKg`, `liquidHeatCapacityJPerKgK`) to trigger the matching sizing
  path; missing two-phase inputs are reported as warnings, not failures.
- Adequacy is judged by **area** comparison (`selectedAreaIn2 ≥ requiredAreaIn2`),
  not by re-plugging the selected area into the nozzle equation — API 520
  empirical sizing and the nozzle capacity formula are not inverses.
- Hand the disposal load off to `neqsim-relief-flare-network` for flare-tip and
  header hydraulics. Verified by `OverpressureProtectionStudyTest` +
  `OverpressureExtensionsTest`.

## Common Mistakes

| Mistake                                              | Fix                                                                  |
| ---------------------------------------------------- | -------------------------------------------------------------------- |
| Counting BPCS twice as two IPLs                      | One BPCS = one IPL; control + alarm on same DCS = single layer       |
| Claiming credit for procedural IPL with PFD 0.01     | Operator-action IPL minimum PFD = 0.1 (CCPS) unless trained+timed    |
| Ignoring common-cause between IPLs                   | Same sensor / same final element ⇒ shared failure, halve credit      |
| Setting target frequency = "fatality"                | Use tolerable individual risk × exposed persons × outcome conditional |
| Picking SIL by "feel"                                | Always derive from LOPA gap (RRF needed) or risk-matrix calibration |
| Forgetting proof-test interval in PFD                | PFDavg ≈ λ_DU × T_proof / 2; double T → double PFD                   |

## Validation Checklist

- [ ] Each IPL satisfies CCPS independence/specificity/auditability
- [ ] No common-cause between adjacent IPLs (sensor, valve, logic solver)
- [ ] BPCS PFD ≥ 0.1; operator-action PFD ≥ 0.1
- [ ] Target frequency cites a corporate or regulatory criterion
- [ ] SIL claimed ≤ SIL achieved by PFD_avg
- [ ] Spurious-trip rate documented (production impact)
- [ ] Results saved to `results.json` with `safety_analysis` section + JSON from `LOPAResult.toJson()` / `SILVerificationResult.toJson()`

## Verification Tests

```bash
./mvnw test -Dtest=Nog070SilCatalogueTest,Sts0131GateTest,Api14cSafeChartBuilderTest,NorsokP002ComplianceCheckerTest,EsdResponseTimeSimulatorTest,OverpressureProtectionStudyTest,OverpressureExtensionsTest
```

## Related Skills

- [`neqsim-relief-flare-network`](../neqsim-relief-flare-network/SKILL.md) — when LOPA shows PSV is the IPL of last resort
- [`neqsim-trapped-liquid-fire-rupture`](../neqsim-trapped-liquid-fire-rupture/SKILL.md) — blocked-in liquid fire rupture, PFP demand, and source-term handoff
- [`neqsim-dynamic-simulation`](../neqsim-dynamic-simulation/SKILL.md) — depressurization & blowdown
- [`neqsim-standards-lookup`](../neqsim-standards-lookup/SKILL.md) — IEC 61508/61511, NORSOK Z-013, API 754