physical-security · git:20261109.2971dcb · 2026-11-09 · sha256 6696cb4f478be7c9
physical-security git:20261109.2971dcbA
Immutable. This exact content never changes and is served at /api/v1/blob/6696cb4f478be7c9.
No tool to install first
claude plugin marketplace add https://markdownregistry.com/mp/a/art_gnsaywzav5aekthw/6696cb4f478be7c9a46617b36bbe21d6027d05cc1f662da5341aeab743f0e052.json
Then /plugin install physical-security@markdownregistry-gnsaywzav5aekthw in Claude Code. It installs this exact version, the one graded A here, pinned to the commit it was graded at, and leaves it there.
--- name: physical-security description: Layered physical controls for facilities and data centers — tailgating defense, badge/visitor/CPTED, environmental resilience, and where physical access becomes cyber compromise. license: Apache-2.0 metadata: verified: "2026-10-20" --- # Physical security (defense-in-depth) Physical access defeats most cyber controls — a person at the keyboard, the console port, or the disk wins. Design in concentric layers so bypassing one control still leaves the attacker outside the next: **deter → detect → delay → respond → recover**. No single fence, lock, or guard is the control; the overlap is. This is the defensive counterpart to physical/social-eng offense (`load_skill social-engineering-defense` for the human layer). ## Concentric zones (outer → inner) - **Perimeter** — lighting, fencing, bollards/barriers, signage. CPTED's three levers: natural surveillance (sightlines, no blind corners), natural access control (one obvious funneled entry), territorial reinforcement (clear public vs private boundary). Goal: deter and channel, not just wall off. - **Building shell** — badge-controlled entry, reception as a real checkpoint, no propped doors (door-held-open alarms), CCTV with retention ≥ 90 days. - **Interior zones** — escalating credentials per sensitivity. Floors/wings segmented; a building badge ≠ a data-hall badge. - **Secure room / cage / rack** — MFA at the door (badge + PIN or badge + biometric), and the rack itself locked. Smallest blast radius gets strongest control. ## Data-center / high-value facility controls - **Mantrap / interlocking vestibule** at the data hall: two doors, only one opens at a time, one person per cycle — the structural anti-tailgating control. - **Anti-passback**: a badge that entered can't enter again without an exit swipe — kills badge-sharing and pass-back. Enforce in + out sequencing. - **MFA on sensitive zones**: badge + PIN / biometric / mobile credential. - **CCTV + alarm fusion**: cameras on every door, alarms on forced/held doors, recorded and tied to badge events for after-the-fact reconstruction. - **Asset control**: media/equipment in-out logging; no personal devices in the hall; sanitize or shred decommissioned drives (NIST SP 800-88). - verify (controls checklist): https://www.cisa.gov/topics/physical-security ## Tailgating / piggybacking defense - The hardest human-layer problem: people hold doors out of politeness. - Structural fixes beat policy: mantraps, full-height turnstiles, optical speed-lanes — one credential, one person. - Detective: door-ajar alarms, anti-passback violations, video analytics for two-bodies-one-swipe, periodic badge-vs-presence audits. - Cultural: "badge every person, every time," challenge-and-escort norm, no shame for asking a stranger to badge in. Reinforce via `load_skill security-awareness`. ## Visitor & badge management - Pre-registration tied to a named internal sponsor + a time window. - Photo ID check at sign-in; time-limited, visually distinct visitor badge; escort required in non-public zones; sign-out enforced. - Employee badges: provisioned via joiners/movers/leavers workflow synced to HR — **same-day revoke on termination** is the control that actually matters. Periodic access recertification; deprovision orphaned/loaner badges. - Contractors/vendors get scoped, expiring access — never permanent. ## Environmental & availability controls - **Power**: dual feeds, UPS for ride-through, generator + fuel contract; test failover on a schedule (an untested generator is decoration). - **HVAC/cooling**: redundant units, temp/humidity monitoring with alerting — thermal shutdown is an outage. - **Fire**: VESDA early smoke detection + clean-agent (inert gas) suppression in data halls; never water over live equipment. Annual inspection. - **Water/flood**: leak detection under raised floor; no equipment below grade in flood zones. ## Where physical meets cyber (the crossover risks) - **Console / OOB access**: a serial/iLO/iDRAC/IPMI port is unauthenticated god-mode. Lock the rack, disable unused ports, credential the BMC, segment its mgmt network. - **USB / removable media**: drop-key and BadUSB attacks bypass the perimeter. Disable/whitelist USB, epoxy or port-block where feasible, enforce DLP. - **Evil-maid**: unattended/unencrypted device = full compromise via boot. Full-disk encryption with TPM + pre-boot PIN, Secure Boot, tamper-evident seals on travel laptops. - **Shoulder-surf / clean-desk**: privacy screens, auto-lock, locked drawers, shred bins. Whiteboards and sticky notes are recon gold for an on-site attacker. - **Network jacks / rogue devices**: 802.1X / MAC-auth on physical ports; disable unused jacks in lobbies/conference rooms; rogue-AP and unknown-device detection. ## Measure it - Tailgating-test pass rate (red-team physical entry attempts caught). - Mean time to revoke badge on termination (target: same business day). - % doors with working alarm + camera coverage; % access reviews completed on time. - Failover test cadence met (power/cooling/fire) — pass/fail, not "documented."