name: neqsim-depressurization-mdmt
version: "1.0.0"
description: "Emergency depressurization (blowdown) per API 521 §5.20 and minimum design metal temperature (MDMT) assessment per ASME UCS-66 / API 579 / EN 13445 — VU-flash transient inventory model, time-to-target-pressure, low-temperature embrittlement screening, and integration with PSV/flare loads. USE WHEN: a task requires sizing a blowdown valve, generating a P-vs-time curve for a vessel under fire / depressurization, checking MDMT against blowdown end-temperature, providing source terms for relief and flare networks, or distinguishing blowdown from trapped-liquid fire rupture screening. Anchors on neqsim.process.safety.depressurization.DepressurizationSimulator and neqsim.process.safety.mdmt.MDMTCalculator."
last_verified: "2026-04-26"
requires:
java_packages:
- neqsim.process.safety.depressurization
- neqsim.process.safety.mdmt
---
# NeqSim Depressurization & MDMT Skill
Transient blowdown / depressurization for inventory release on fire or
controlled emergency, plus the minimum design metal temperature (MDMT) check
that drives material selection. The two are linked: blowdown end-temperatures
(often −80 to −120 °C for hydrocarbon gas) usually drive MDMT, which in turn
drives whether LTCS, low-temperature carbon-Mn, 3.5 % Ni or 9 % Ni / 304L is
required.
## When to Use
- Sizing a blowdown / depressurization valve to reach 50 % pressure in 15 min
(API 521 §5.20 fire case) or 7 bar in some operator standards
- Generating P(t), T(t), m(t) curves for the relief / flare load case
- Screening MDMT against end-of-blowdown vessel-wall temperature
- Producing source terms for the flare network (`neqsim-relief-flare-network`)
- Distinguishing depressurization cases from blocked-in liquid fire rupture cases,
where `neqsim-trapped-liquid-fire-rupture` is the primary workflow
Distinct from `neqsim-relief-flare-network` (steady-state PSV sizing) and
`neqsim-dynamic-simulation` (continuous-process transients) — this skill is the
specific blowdown + MDMT pair.
## Standards
- **API 521** 7th ed. — Pressure-relieving and depressuring systems (§5.20 blowdown)
- **API STD 520** — PSV sizing, used for choke check at the BDV
- **ASME UCS-66 / UCS-66.1** — MDMT impact-test exemption curves (carbon steel)
- **ASME UHA-51** — austenitic stainless steel low-temperature service
- **API 579 / FFS-1 §3** — fitness-for-service, MDMT for in-service vessels
- **EN 13445-2 Annex B** — European MDMT and impact-test approach
- **NORSOK L-002** — piping system design (low-temperature operation)
## Method 1 — Blowdown Simulation (VU-flash)
```java
import neqsim.thermo.system.SystemSrkEos;
import neqsim.thermo.system.SystemInterface;
import neqsim.process.safety.depressurization.DepressurizationSimulator;
SystemInterface gas = new SystemSrkEos(273.15 + 50.0, 100.0);
gas.addComponent("methane", 0.92);
gas.addComponent("ethane", 0.05);
gas.addComponent("propane", 0.03);
gas.setMixingRule("classic");
gas.setTotalNumberOfMoles(5000.0); // mol — representative of vessel inventory
DepressurizationSimulator sim = new DepressurizationSimulator(gas);
sim.setVesselVolume(50.0); // m³
sim.setOrificeArea(5.0e-4); // m² — BDV equivalent area
sim.setBackPressure(1.5); // bara — flare KO drum
sim.setHeatInput(0.0); // adiabatic; > 0 for fire case
sim.run(900.0, 1.0); // 15 min, 1 s timestep
double[] t = sim.timeSeries();
double[] p = sim.pressureSeries();
double[] T = sim.temperatureSeries();
double[] m = sim.massFlowSeries();
double pEnd = p[p.length - 1];
double tEnd = T[T.length - 1];
double t50 = sim.timeToPressure(50.0); // s, time to 50 bar
```
The simulator uses the U–V flash (`ops.VUflash(V, U)`) at every step — internal
energy decreases by `h_out · ṁ · Δt` and volume is held constant by the vessel,
so each step is a fully consistent thermodynamic state. Joule-Thomson cooling
across the BDV is captured via an isenthalpic flash to the back pressure for the
exit-temperature output.
### Fire case
```java
sim.setHeatInput(60_000.0); // W — API 521 fire heat input
```
API 521 fire heat input on uninsulated vessels:
`Q = 43.2 · F · A^0.82 [W]`
with environment factor F (= 1.0 for un-insulated, 0.30 for fireproof
insulation, 0.075 for water-spray) and wetted area A in m². The simulator
accepts the value directly so any of the API 521, NFPA 30 or NORSOK
correlations can be used upstream.
## Method 2 — BDV Sizing Iteration
Typical workflow:
1. Start from a target such as 50 % of design pressure in 15 min (API 521), 7 bar in 15 min, or the relevant company/project criterion from the private basis.
2. Guess BDV `Cd · A`, run `sim.run(...)`, read `sim.timeToPressure(target)`.
3. Iterate area until target is met without choking the flare header.
4. Verify the *minimum* T(t) is above the vessel MDMT.
A reference iteration loop is available as
`DepressurizationSimulator.sizeForTargetPressure(targetBar, targetTimeS)`.
## Method 3 — MDMT Assessment
```java
import neqsim.process.safety.mdmt.MDMTCalculator;
MDMTCalculator mdmt = new MDMTCalculator();
mdmt.setMaterial("SA-516-70N"); // normalised CMn, common for CS vessels
mdmt.setThicknessMM(50.0);
mdmt.setStressRatio(0.35); // operating / allowable stress ratio
double mdmtC = mdmt.computeUCS66(); // °C — ASME UCS-66 + UCS-66.1 reduction
```
The calculator implements:
- **UCS-66 Curve A / B / C / D** lookup vs material specification
- **UCS-66.1** stress-ratio reduction (lower stress → lower MDMT)
- **API 579 §3** Fitness-for-Service path for in-service vessels with crack
reassessment factors
- **EN 13445-2** Annex B alternative if requested
### Pass / fail check
```java
double bdvEndTemp = sim.minTemperatureC(); // °C from blowdown sim
boolean acceptable = bdvEndTemp >= mdmtC;
if (!acceptable) {
// Either: thicker vessel, lower stress ratio, LTCS / 3.5%Ni material,
// slower BDV, or accept impact testing per UG-84.
}
```
Many company practices add a 5-10 °C margin between blowdown end-temperature
and MDMT. Record the actual project or operator margin in the private task
basis instead of hard-coding it in public guidance.
## Method 4 — Source Term to Flare Network
```java
double[] mdot = sim.massFlowSeries();
double[] T = sim.temperatureSeries();
double[] P = sim.pressureSeries();
// Pass to ReliefValveSizing peak-load aggregator or to
// FlareStack.estimateRadiationHeatFlux at peak ṁ.
double mdotPeak = sim.peakMassFlow();
```
This is the standard handoff between the depressurization model and the flare
network sizing skill (`neqsim-relief-flare-network`).
## Method 5 — Coupled Multi-Vessel Blowdown to a Shared Header (API 521 §7)
When several vessels blow down simultaneously into one flare/disposal header, the
**combined** load — not any single vessel — sizes the header. `MultiVesselBlowdownStudy`
superimposes each source on a common time grid and checks the header Mach at the peak.
```java
import neqsim.process.safety.depressurization.MultiVesselBlowdownStudy;
import neqsim.process.safety.depressurization.MultiVesselBlowdownStudy.MultiVesselBlowdownResult;
MultiVesselBlowdownResult res = new MultiVesselBlowdownStudy()
.addSource("V-100", bdvSim100) // configured DepressurizationSimulator
.addSource("V-200", bdvSim200)
.addSourceResult("V-300", precomputed) // or a pre-computed DepressurizationResult
.setHeader(0.6, 1.5, 288.15, 0.020, 1.30) // D[m], P[bara], T[K], M[kg/mol], gamma
.setMaxAllowableMach(0.70) // API 521 §7 / NORSOK P-002
.run();
double peak = res.getPeakTotalMassFlowKgPerS();
double tPeak = res.getPeakTimeS();
double mach = res.getHeaderMach();
boolean okMach = res.isHeaderMachAcceptable();
String report = res.summary();
```
Use `addSourceResult(...)` with a pre-computed `DepressurizationResult` to avoid
re-running the (slow) VU-flash transient for vessels already simulated.
## Method 5b — Governed STID/TR2000 Dynamic Blowdown + Flare Handoff
For agentic engineering studies that start from STID/P&ID drawings, line lists,
equipment lists, and TR2000 pipe/valve/material evidence, use the governed data
source and runner instead of stitching transient notebooks together by hand.
Key classes:
- `LineEquipmentListEvidence` — reviewed line-list and equipment-list rows used
to build the dynamic model.
- `DynamicBlowdownFlareStudyDataSource` — source-traceable package with one
`BlowdownSource` per protected equipment item plus header, flare, PSV, fire,
topology, and evidence status.
- `DynamicBlowdownFlareStudyRunner` — runs `DepressurizationSimulator`, aggregates
loads with `MultiVesselBlowdownStudy`, sizes PSV orifices through
`ReliefValveSizing`, and estimates peak/cumulative flare heat, emissions,
radiation distance, and capacity utilization.
- `DynamicBlowdownFlareStudyHandoff` — versioned JSON package containing
`dynamic_blowdown_flare_result.v1` and `dynamic_blowdown_flare_load_handoff.v1`.
```java
LineEquipmentListEvidence lineEq = LineEquipmentListEvidence.builder("line-eq-001")
.lineListReviewed(true)
.equipmentListReviewed(true)
.addEquipment("V-100", "separator", 50.0, 85.0, 70.0, 313.15)
.addLine("BD-100", "V-100", "FLARE-HDR", 6.0, 0.154, 0.007, 45.0, "DD100", "API 5L X52")
.build();
DynamicBlowdownFlareStudyDataSource.BlowdownSource source =
DynamicBlowdownFlareStudyDataSource.BlowdownSource.builder("V-100", gas)
.equipmentTag("V-100")
.vesselVolumeM3(50.0)
.orificeDiameterM(0.035)
.dischargeCoefficient(0.72)
.backPressureBara(1.5)
.api521FireCase(120.0, true, true)
.psvBasis(85.0, 0.21, false, false)
.build();
DynamicBlowdownFlareStudyDataSource data = DynamicBlowdownFlareStudyDataSource.builder("BD-FLARE-001")
.lineEquipmentListEvidence(lineEq)
.addSource(source)
.flareHeader(0.6, 1.5, 288.15, 0.020, 1.30)
.flareGeometry(0.8, 50.0, 0.20)
.stidDiagramReviewed(true)
.lineEquipmentListsReviewed(true)
.vesselInventoryReviewed(true)
.valveSizingBasisReviewed(true)
.psvBasisReviewed(true)
.flareSystemBasisReviewed(true)
.fireCaseReviewed(true)
.standardsReviewed(false)
.build();
DynamicBlowdownFlareStudyHandoff handoff = DynamicBlowdownFlareStudyRunner.builder()
.timeStepSeconds(1.0)
.maxTimeSeconds(900.0)
.build()
.run(data);
```
Readiness semantics mirror the pipe-fire runner: missing source fluid, volume,
BDV/orifice diameter, discharge coefficient, or flare backpressure blocks the
calculation; missing reviewed topology, TR2000, PSV, fire, or flare capacity
evidence keeps the result at screening level.
## Method 6 — ESD Response-Time Budget (NOG 070 / IEC 61511)
The blowdown / isolation only mitigates the relief load if the ESD valve actually
closes in time. `EsdResponseTimeSimulator` sums the SIF loop contributions and
compares against the allowable budget.
```java
import neqsim.process.safety.esd.EsdResponseTimeSimulator;
import neqsim.process.safety.esd.EsdResponseTimeSimulator.EsdResponseTimeResult;
EsdResponseTimeResult esd = new EsdResponseTimeSimulator()
.setSifTag("SIF-2001 ESDV closure")
.addDetection("PT-2001 detection", 2.0) // s
.addLogic("Logic solver scan + 2oo3 vote", 0.5)
.addValve("ESDV-2001 close", 1.0, 18.0) // solenoid delay, valve stroke
.setAllowableResponseTimeS(45.0)
.evaluate();
double total = esd.getTotalResponseTimeS();
double margin = esd.getMarginS();
boolean ok = esd.isWithinBudget();
```
This is a budgeting tool — it does not replace certified SIS proof testing or
FAT/SAT. Pair with `neqsim-process-safety` for the SIL determination of the SIF.
## Method 7 — Vessel Thermomechanical Safety Models
When a single-temperature lumped model is not enough — gas/liquid temperature
bifurcation in a fire, transient PSV sizing conservatism, fast filling, cryogenic
boil-off, through-wall thermal lag, or wall rupture — use the dedicated
thermomechanical classes. They reproduce the application cases of Andreasen
(2026), *J. Loss Prev. Process Ind.* 103, 106088, and are covered by committed
regression tests. See `docs/safety/vessel_thermomechanical_safety.md` for the
full guide.
```java
// Two-temperature (non-equilibrium) fire blowdown — gas superheats, liquid stays cold
import neqsim.process.safety.depressurization.NonEquilibriumBlowdownModel;
import neqsim.process.safety.depressurization.NonEquilibriumBlowdownModel.NemResult;
NonEquilibriumBlowdownModel nem =
new NonEquilibriumBlowdownModel(fluid, 10.0, 0.025, 0.72, 1.0e5);
nem.setFireExposure(0.9, 1100.0, 30.0, 25.0).setWall(8000.0, 470.0);
nem.setTimeStep(1.0).setMaxTime(600.0).setStopPressure(1.5e5);
NemResult bd = nem.run();
double bifurcationK = bd.maxTemperatureBifurcationK;
// Dynamic PSV sizing — quantify API 521 steady-state oversizing (§4.1)
import neqsim.process.safety.depressurization.DynamicPsvSizingStudy;
DynamicPsvSizingStudy.SizingComparison cmp =
new DynamicPsvSizingStudy(gas, 1.0, 150000.0, 11.0e5, 0.21, 1.0e5)
.setBlowdownFraction(0.1).setDischargeCoefficient(0.975).run();
double oversizing = cmp.oversizingRatio; // > 1 => steady-state conservative
// Fast filling of a Type IV hydrogen cylinder — liner temperature limits (§4.2)
import neqsim.process.safety.depressurization.VesselFillingSimulator;
VesselFillingSimulator.VesselFillingResult fill =
new VesselFillingSimulator(h2, 0.06)
.setInletConditions(283.15, 360.0, 0.015)
.setTargetPressure(351.0)
.setLinerTemperatureLimits(233.15, 338.15)
.setTimeStep(1.0).setMaxTime(4000.0).run();
boolean linerOk = fill.linerLimitsMet;
// Cryogenic boil-off vs insulation thickness (§4.3)
import neqsim.process.util.heattransfer.BoilOffCalculator;
double boilOff = new BoilOffCalculator()
.setSurfaceArea(150.0).setOuterFilmCoefficient(10.0)
.setInsulationConductivity(0.025).setAmbientTemperatureK(288.15)
.setFluidTemperatureK(253.15).setLatentHeat(320000.0)
.boilOffRateKgPerH(0.30);
// Fire/blowdown wall rupture vs temperature-derated strength (§4.4)
import neqsim.process.safety.rupture.VesselRuptureAnalyzer;
import neqsim.process.safety.rupture.MaterialStrengthCurve;
MaterialStrengthCurve steel = MaterialStrengthCurve.carbonSteel("CS", 245.0e6, 415.0e6);
VesselRuptureAnalyzer.VesselRuptureResult rup =
new VesselRuptureAnalyzer(0.5, 0.012, steel).analyze(timeS, pressurePa, metalTempK);
boolean ruptured = rup.ruptured; // bare LPG vessel ruptures in minutes; PFP prevents it
```
Supporting classes: `CompositeWallConduction` (1D transient multi-layer wall,
Crank-Nicolson; use the static `biotNumber(...)` helper — lumped is fine for
`Bi < 0.1`), `VesselHeatTransferCorrelations` (Woodfield filling Nusselt,
Rohsenow nucleate boiling), and `BlockedOutletOverpressureAnalyzer` (blocked-in
charging overpressure with relief-demand flag).
## Common Pitfalls
- **Adiabatic vs fire case** — running adiabatic blowdown gives the *coldest*
end-temperature (worst for MDMT). Running fire case gives the *highest peak
flow* (worst for flare network). Both must be checked separately.
- **Single component vs multi-component** — MDMT is driven by the
end-of-blowdown temperature, which depends on JT coefficient and is sensitive
to ethane / propane content. Always use a representative composition, not a
pure-methane simplification.
- **Ignoring liquid level** — vessels with liquid have huge thermal mass; the
gas phase cools quickly while the liquid holds temperature. The simulator
handles two-phase systems automatically.
- **Choked vs sub-critical flow** — the BDV chokes for most of the blowdown.
Make sure the simulator's flow model uses choked-flow correlations until
P_vessel / P_back < 1/r_critical.
- **Stress ratio = 1** — using 1.0 for stress ratio gives the most conservative
MDMT. Operating-pressure stress ratio (0.30–0.40) usually relaxes MDMT by
10–30 °C.
## Verification Tests
```bash
./mvnw test -Dtest=DepressurizationSimulatorTest,MDMTCalculatorTest,MultiVesselBlowdownStudyTest,EsdResponseTimeSimulatorTest
./mvnw test -Dtest=DynamicPsvSizingStudyTest,VesselFillingSimulatorTest,VesselRuptureAnalyzerTest,BoilOffCalculatorTest
```
## See Also
- `neqsim-relief-flare-network` — PSV sizing, flare radiation, header back-pressure
- `neqsim-trapped-liquid-fire-rupture` — blocked-in liquid thermal expansion, PFP demand, and rupture source-term handoff
- `neqsim-dynamic-simulation` — continuous-process transients with controllers
- `neqsim-consequence-analysis` — what happens after the released gas ignites
- `neqsim-flow-assurance` — JT cooling and hydrate formation in blowdown
- `neqsim-process-safety` — LOPA / SIL for the blowdown SIF (BDV-SIF)