--- type: Skill name: taipower-indoor-wiring-ampacity description: "This skill should be used when calculating or verifying the allowable ampacity (current-carrying capacity) of indoor electrical wiring and conduit fill limits according to the Taipower Indoor Wiring Regulations (屋內線路裝置規則)." metadata: class: B --- # Taipower Indoor Wiring Ampacity & Conduit Fill ## Context & Purpose This skill encodes the regulations for indoor electrical wiring (屋內線路裝置規則) specifically focusing on the allowable ampacity of wires inside conduits (PVC or Metal) and ambient temperature corrections. ## Parameters & Tables (Based on Article 16) ### 1. Baseline Conditions - **Standard Ambient Temperature**: 35°C - **Standard Conductor Insulation Temp**: 60°C (e.g., PVC), 75°C (e.g., XLPE/PE), or 90°C. - **Wire Material**: Copper (銅) ### 2. Ampacity for PVC Wire in Conduit (60°C Insulation, 35°C Ambient) - Partial Table (Table 16-7) | Wire Size (mm²) | Ampacity for ≤ 3 wires | Ampacity for 4 wires | Ampacity for 5-6 wires | |-----------------|------------------------|----------------------|------------------------| | 2.0 mm (Solid) | 19 A | 16 A | 14 A | | 3.5 mm² | 19 A | 16 A | 14 A | | 5.5 mm² | 25 A | 23 A | 20 A | | 8 mm² | 33 A | 30 A | 25 A | | 14 mm² | 50 A | 40 A | 35 A | | 22 mm² | 60 A | 55 A | 50 A | | 38 mm² | 85 A | 75 A | 65 A | | 50 mm² | 100 A | 90 A | 80 A | | 100 mm² | 160 A | 150 A | 125 A | *(Note: Neutral wire, grounding wire, and control wires are generally not counted in the "number of wires" for ampacity derating, unless harmonics are present).* ### 3. Voltage Drop (Article 9) - **Feeder + Branch Circuit**: Total voltage drop must not exceed **5%** of the nominal voltage. - **Feeder only or Branch only**: Voltage drop must not exceed **3%**. ## Execution Logic for AI When reviewing a single-line diagram (單線圖) or wiring schedule: 1. Identify the wire size (e.g., 8 mm²) and the number of current-carrying conductors in the conduit. 2. Cross-reference with the ampacity table to find the maximum allowed current. 3. Compare the allowed current with the specified breaker size (AT/AF). The wire's ampacity must be ≧ the breaker's trip setting (AT), with exceptions for motor loads. 4. Verify voltage drop calculations do not exceed 3% for branches or 5% total.