accessible-door-clear-width · git:20260807.0499507 · 2026-08-07 · sha256 5f2fd961b120ea8c
accessible-door-clear-width git:20260807.0499507A
Immutable. This exact content is served forever at /api/v1/blob/5f2fd961b120ea8c.
--- type: Skill name: accessible-door-clear-width description: "This skill should be used when checking accessible-route door/opening clear-width compliance for buildings in Taiwan, and avoiding the gap between the code's nominal frame-to-frame distance and the effective passable clear width after the door leaf, hardware and finishes intrude. Covers Taiwan Accessible Facilities Design Specification §205.2.3 (entrances/doors): hinged-door frame-to-frame distance ≥ 90 cm, sliding/folding-door clear width ≥ 80 cm, no thresholds, and the §205.4.1 ban on revolving/spring doors." user-invocable: true metadata: class: C --- # Accessible Door Clear Width Pitfalls (無障礙出入口門淨寬實務陷阱) ## Overview The code measures the **frame-to-frame distance**; a person passes through the **effective clear width after the door opens**. The difference is consumed by the door leaf, hardware and finishing layers. Invoke this skill when: - Sizing door openings on an accessible route - Deciding whether to reserve width for door-leaf intrusion and finishes - Self-checking before accessible-facility completion inspection --- ## Core Principle: Nominal Opening ≠ Effective Passable Clear Width The provision measures the **frame-to-frame distance** (hinged door ≥ 90 cm), but the usable dimension is the **effective clear width with the door open 90°** (inner face of the open leaf to the opposite frame). The difference: ``` nominal frame-to-frame distance − door-leaf/hardware intrusion (at 90°) − two-side finishing = effective passable clear width ``` The threshold is "≥", so an opening drawn exactly at 90 cm almost certainly fails after the leaf and finishes are installed. --- ## Pitfall Card: Accessible Door Clear Width — Effective-Clear-Width Trap | Field | Value | |---|---| | **Regulatory basis** | Taiwan Accessible Facilities Design Specification **§205.2.3 (entrances/doors)**; revolving/spring doors banned (§205.4.1) | | **Threshold** | Hinged door: **frame-to-frame distance ≥ 90 cm**; sliding/folding door: **clear width after opening ≥ 80 cm**. Floor flush, no threshold | | **Measurement nuance** | Code text measures "frame-to-frame distance"; practice/inspection commonly judges by **effective clear width** (door open 90°, inner leaf face to opposite frame). Leaf thickness, stops, handles and finishes all erode it | | **Gap mechanism** | nominal frame-to-frame − leaf/hardware intrusion − two-side finishing = effective passable clear width (forfeits compliance below 90 cm) | | **Drawing countermeasure** | Draw the opening at **100 cm**, reserving for leaf intrusion and finishing, so effective clear width stays ≥ 90 cm | | **Failure consequence** | effective clear width < 90 cm → accessible-facility inspection fails → use permit blocked | | **Failure timing** | Surfaces after the door and finishes are installed; hard to remediate (requires changing door type or rebuilding the frame) | | **Linked items** | accessible-route clear width along the whole path, interior fit-out, use-permit completion inspection | | **Severity** | 🔴 High (directly blocks the use permit; a late-stage, post-completion risk) | > Mnemonic: the 90 cm must be measurable after the door is hung and finishes applied; draw 100 cm so the leaf and cladding are given away up front. --- ## Design Checks - [ ] Hinged-door opening reserves leaf intrusion + finishing (frame-to-frame ≈95–100 cm so effective ≥ 90 cm)? - [ ] No revolving/spring doors (§205.4.1)? - [ ] Floor flush, no threshold? - [ ] Sliding/folding door clear width ≥ 80 cm after opening? - [ ] Handle leaves 4–6 cm anti-pinch space (§205.4.3)? ## To Verify - The "effective clear width judged at 90° open" is a practice/inspection convention; the code text states "frame-to-frame distance". Confirm against local-government inspection interpretations. ## References - Taiwan Accessible Facilities Design Specification §205 (entrances/doors) — Ministry of the Interior regulation system - Local-government use-permit accessible-facility inspection rules