18-ot-ics-security · v3.1.0 · 2026-09-07 · sha256 5b9959a0deaeaa6f
18-ot-ics-security v3.1.0A
Immutable. This exact content never changes and is served at /api/v1/blob/5b9959a0deaeaa6f.
--- name: OT / ICS / SCADA Security description: Operational Technology and industrial control system security — Purdue model segmentation, industrial protocol analysis (Modbus, DNP3, S7, EtherNet/IP), PLC/HMI exposure, IEC 62443 alignment, and MITRE ATT&CK for ICS, for authorized and safety-conscious assessments version: 3.1.0 author: Masriyan tags: [cybersecurity, ot-security, ics, scada, modbus, dnp3, plc, iec62443, attack-ics, purdue-model] --- # OT / ICS / SCADA Security ## Purpose Enable Claude to assess Operational Technology (OT) and Industrial Control System (ICS) environments — PLCs, RTUs, HMIs, SCADA servers, historians, and field devices — with **safety as the first constraint**. Claude reasons about the Purdue/ISA-95 model, analyzes industrial protocols passively, maps adversary behavior to **MITRE ATT&CK for ICS**, and aligns recommendations to **IEC 62443** and the **NIST SP 800-82** guidance. > **SAFETY & AUTHORIZATION — READ FIRST**: OT systems control physical processes; a crashed PLC can mean equipment damage, environmental release, or loss of life. **Default to passive, non-intrusive methods.** Never send active scans, writes, or protocol fuzzing to production OT without written authorization, asset-owner sign-off, and a tested rollback/safety plan — ideally on a test bench or during a maintenance window. Confirm scope and the "do-no-harm" boundary before proceeding. --- ## Activation Triggers This skill activates when the user asks about: - ICS / SCADA / OT / DCS security or industrial network assessment - Modbus, DNP3, S7comm, EtherNet/IP, BACnet, OPC-UA, IEC 61850/104 protocols - PLC, RTU, HMI, historian, or engineering-workstation security - Purdue model / ISA-95 segmentation and IT/OT boundary review - IEC 62443, NIST SP 800-82, or NERC CIP alignment - MITRE ATT&CK for ICS technique mapping - Internet-exposed ICS devices (Shodan/Censys dorks) or ICS asset inventory - OT threat detection, anomaly monitoring, or ICS incident response --- ## Prerequisites ```bash pip install requests pyyaml # Protocol libraries (lab use): pip install pymodbus scapy ``` **Optional enhanced capabilities:** - Wireshark / `tshark` with ICS dissectors (Modbus, DNP3, S7, ENIP, GOOSE) - `nmap` ICS NSE scripts (use read-only scripts only, with care) - GRASSMARLIN / passive asset-discovery tooling - Shodan/Censys access for exposure checks (passive, external) --- ## Core Capabilities ### 1. Architecture & Purdue Model Review When asked to review OT architecture, map assets to Purdue levels and assess the boundaries: | Level | Zone | Assets | Key control | |-------|------|--------|-------------| | 4–5 | Enterprise / IT | ERP, business network, internet | Should never directly reach L0–L2 | | 3.5 | **IDMZ** | Jump hosts, patch/AV relays, historian replica | Brokered, inspected IT↔OT traffic only | | 3 | Operations | SCADA servers, historians, engineering WS | Hardened, monitored | | 2 | Supervisory | HMIs, control servers | | | 1 | Control | PLCs, RTUs, IEDs | | | 0 | Process | Sensors, actuators, drives | | Flag: missing IDMZ, flat IT/OT networks, dual-homed engineering workstations, remote vendor access bypassing the DMZ, and any direct path from L4/L5 to L0–L2. ### 2. Industrial Protocol Analysis (Passive-First) Prefer reading a SPAN/TAP capture over active probing. From a PCAP, identify: - **Modbus/TCP (502)** — function codes; flag writes (FC 5/6/15/16), unauthenticated reads, exposure beyond the cell. - **DNP3 (20000)** — operate/direct-operate, lack of Secure Authentication (SAv5). - **S7comm / S7comm-plus (102)** — PLC start/stop, program upload/download. - **EtherNet/IP + CIP (44818/2222)** — forward-open, attribute writes. - **OPC-UA (4840)** — security policy `None`, anonymous sessions. - **IEC 61850 GOOSE/MMS, IEC 60870-5-104 (2404), BACnet (47808)** as present. Note that **most ICS protocols have no authentication or encryption by design** — any reachable client can issue commands. Use `scripts/ics_protocol_analyzer.py` to summarize an exported PCAP and flag write/control operations and unexpected talkers. ### 3. Exposure & Asset Discovery - **Passive inventory** from captures (MAC/OUI → vendor, protocol → device role). - **External exposure** (read-only, external) via Shodan/Censys dorks — never expose live device details publicly: - `port:502 product:Modbus`, `port:20000 source address`, `tag:ics`, `"Siemens, SIMATIC"`, `port:47808`, `"Schneider Electric"`. - For any device that *must* be reachable, document why, the compensating controls, and whether it should be behind the IDMZ instead. - Active scanning, if authorized: use only read-only `nmap` NSE (`modbus-discover`, `s7-info`, `bacnet-info`, `enip-info`) with low rate, never against safety-instrumented systems (SIS). ### 4. Threat Modeling — MITRE ATT&CK for ICS Map plausible adversary paths using the ICS matrix tactics: Initial Access → Execution → Persistence → Evasion → Discovery → Lateral Movement → Collection → Command-and-Control → **Inhibit Response Function** → **Impair Process Control** → **Impact**. Reference high-signal techniques (e.g., T0883 Internet-Accessible Device, T0836 Modify Parameter, T0831 Manipulation of Control, T0814 Denial of Service, T0816 Device Restart/Shutdown). Anchor scenarios to real tradecraft (Stuxnet, TRITON/TRISIS targeting SIS, Industroyer/CRASHOVERRIDE, PIPEDREAM/INCONTROLLER). ### 5. IEC 62443 / NIST SP 800-82 Alignment - Define **zones and conduits**; assign **Security Levels (SL 1–4)** per zone based on threat. - Review against IEC 62443-3-3 system requirements (FR1 IAC, FR2 UC, FR3 system integrity, FR4 data confidentiality, FR5 restricted data flow, FR6 timely response, FR7 resource availability). - Map to NIST SP 800-82r3 control overlays and NERC CIP where the asset owner is in scope (BES). ### 6. OT-Aware Detection & Incident Response - Detection: baseline normal protocol talkers and command rates; alert on unexpected write/program-download, new engineering connections, off-hours commands, and L4→L1 traffic. - IR (coordinate with → Skill 07, but OT-modified): **safety and process continuity outrank evidence preservation**; involve process/safety engineers; prefer passive collection; have a manual-operations fallback before isolating anything. --- ## Output Standards ```markdown # OT/ICS Security Assessment — [Site / System] Date: [Date] | Scope: [Zones/Assets] | Method: [Passive/Active] | Analyst: [Name] Safety constraints honored: [yes — passive only / window used / etc.] ## Executive Summary [Posture, top safety-relevant risks] ## Purdue / Zone-Conduit Map [Levels, boundaries, IDMZ status] ## Findings ### [O-01] Modbus writes reachable from IT VLAN (Critical) - ATT&CK ICS: T0883, T0836 | IEC 62443 FR5 - Evidence: [pcap flow IT-host → PLC FC16] - Process impact: [what physical effect is possible] - Remediation: [conduit/firewall rule, IDMZ broker, read-only segmentation] ## IEC 62443 Zone/SL Recommendations | Zone | Current SL | Target SL | Gap | ## Prioritized Remediation (safety-weighted) ``` --- ## Script Reference ### `ics_protocol_analyzer.py` ```bash # Summarize an exported PCAP CSV/JSON (from tshark) and flag control/write ops tshark -r capture.pcap -T json > capture.json python scripts/ics_protocol_analyzer.py --input capture.json --output ics_report.json # Generate Shodan/Censys exposure dorks for a vendor/protocol set python scripts/ics_protocol_analyzer.py --dorks --vendor siemens --output dorks.txt ``` --- ## Skill Integration | Next Step | Condition | Target Skill | |-----------|-----------|--------------| | Deep PCAP / IDS rules | Network capture available | → Skill 08 | | Firmware / device RE | PLC/RTU firmware obtained | → Skill 04 | | OT incident handling | Active incident | → Skill 07 | | Detection content | SIEM/OT-monitoring rules needed | → Skill 12 | | IT-side segmentation hardening | IT/OT boundary hosts | → Skill 15 | --- ## References - [MITRE ATT&CK for ICS](https://attack.mitre.org/matrices/ics/) - [NIST SP 800-82 Rev. 3 — Guide to OT Security](https://csrc.nist.gov/pubs/sp/800/82/r3/final) - [IEC 62443 series — Industrial Automation and Control Systems Security](https://www.isa.org/standards-and-publications/isa-standards/isa-iec-62443-series-of-standards) - [CISA — ICS Recommended Practices & Advisories](https://www.cisa.gov/topics/industrial-control-systems) - [NERC CIP Standards](https://www.nerc.com/pa/Stand/Pages/CIPStandards.aspx)