name: neqsim-process-modeling
description: "Process modeling and flowsheet construction patterns for NeqSim. USE WHEN: building executable NeqSim process simulations, ProcessSystem flowsheets, or runnable process models with streams, separators, compressors, heat exchangers, valves, pumps, distillation columns, recycles, adjusters, topology checks, result extraction, and engineering validation."
last_verified: "2026-08-22"
---
# NeqSim Process Modeling Skill
Build executable NeqSim process simulations from engineering descriptions. This skill
is the process-flowsheet layer between thermodynamic fluid setup and downstream
specialists such as mechanical design, safety, plant data, and reporting.
## Use When
- Building a `ProcessSystem` or `ProcessModel` flowsheet from a process description.
- Connecting equipment such as streams, separators, compressors, coolers, heaters,
heat exchangers, pumps, valves, pipes, mixers, splitters, recycles, adjusters, and
distillation columns.
- Extracting process results with units, compositions, duties, powers, phase splits,
mass balances, energy balances, or equipment profiles.
- Preparing a steady-state process base case for mechanical design, relief sizing,
flow assurance, dynamic simulation, plant-data comparison, or optimization.
## Core Workflow
1. **Define the fluid** using the EOS and component sequence from
`neqsim-api-patterns`.
2. **Create feed streams** with explicit temperature, pressure, and flow units.
3. **Add equipment in topological order** to a `ProcessSystem`.
4. **Connect by outlet stream objects**, for example separator gas outlet to
compressor inlet or valve outlet to downstream separator.
5. **Run once after assembly** unless recycle initialization requires a staged solve.
6. **Validate results** using conservation checks, phase sanity checks, equipment
limits, and applicable standards.
7. **Report outputs with units** and include assumptions for missing design data.
## Modeling Choices
| Situation | Recommended Pattern |
|-----------|---------------------|
| Single train, linear or branched flowsheet | One `ProcessSystem` |
| Multiple areas with cross-area streams | Multiple `ProcessSystem` objects in a `ProcessModel` |
| Production / gathering / commingling / export **manifold** or inlet header | `Manifold` (`process.equipment.manifold.Manifold`) — NOT `Mixer`/`Splitter` |
| PFD/P&ID or unstructured text input | Use `neqsim-process-extraction` first |
| Distillation or fractionation | Load `neqsim-distillation-design` |
| Startup, shutdown, controllers, inventory dynamics | Load `neqsim-dynamic-simulation` |
| Turndown or control valve operability | Load `neqsim-controllability-operability` |
| Platform-scale separation/recompression | Load `neqsim-platform-modeling` |
**Manifolds:** always model a well/production/gathering/commingling/export
manifold (or an inlet/outlet header) with the `Manifold` class, not a plain
`Mixer` or `Splitter`. Add the routed inlet streams with `addStream(...)`. **A
manifold ALWAYS has split outlets — route downstream from a split stream, never
from `getMixedStream()`.** If the manifold feeds a single destination, give it
one split (`setSplitFactors([1.0])`) and route its `getSplitStream(0)`. For a
distributing manifold set `setSplitFactors([f0, f1, ...])` (fractions summing to
1) and read each branch with `getSplitStream(i)`. `getMixedStream()` returns only
the internal commingled stream (all inlets combined, before the split) — use it
for inspection, not for wiring downstream. The `Manifold` also carries
header/branch inner diameters (`setHeaderInnerDiameter`, `setBranchInnerDiameter`)
for hydraulics and mechanical design.
## Data Basis for an Optimization-Ready Model
A model built only to *run* has fixed operating points. A model built to
**optimize** additionally needs a bounded decision space, equipment constraints,
and an objective. Gather this basis up front (and record every assumed value):
- **Fluid & feed** — composition(s) + PVT/assay (C7+); feed rate, T, P, water
cut/GOR per feed; EOS + mixing rule.
- **Geometry & hydraulics** — **line sizes** (ID, schedule/wall, length, elevation,
roughness, insulation), **manifold/header sizes**, separator/scrubber dimensions
(ID, T/T length, orientation, nozzle sizes), heat-exchanger area/UA.
- **Valves & chokes** — **control-valve Cv/Kv, rated travel, characteristic,
opening**; **choke Cv-vs-opening (bean/trim)** for wells and let-down; ESD sizes.
- **Rotating equipment** — compressor maps (head/eff vs flow at several speeds) +
design/max speed; pump curves (+ NPSHr); driver rating (GT/motor); anti-surge
config (surge line, control-line margin, recycle-valve Cv).
- **Design limits → constraints** — separator design gas-load K + residence time;
compressor rated power, surge/stonewall margins, max discharge T; pump power +
NPSHa; line erosional-velocity limit; design P/T; valve max Cv; MAWP; PSV set P.
- **Decision space & control** — manipulable setpoints with **physical bounds**
(stage pressures, temperatures, compressor discharge P or speed, split/routing);
**compressor control mode** (solve-speed vs predictive — see
`neqsim-agentic-process-optimization`); pre-wired adjusters (do not also optimize).
- **Objective & economics** — objective (max throughput / min power / max value /
min emissions); product specs as constraints (RVP, dew point, cricondenbar,
Wobbe); prices / power & fuel cost / CO2 price for value objectives.
Source geometry and Cv from the line list, valve/choke datasheets, and instrument
index; maps from vendor curve sheets; limits from datasheets + piping class. For
the governed enterprise checklist and readiness gates use
`enterprise-process-model-build-verify` (`target_fidelity="optimization_ready"`).
For MCP `runProcess` compressor protection, keep embedded compressor
`antiSurge` as screening control only. Use root-level `antiSurgeSystems` when
the model must bind `CompressorAntiSurgeApplication` to explicit named hot/cold
recycle valves, cooler, suction mixer, and recycle blocks. Multi-area systems
must include `area`. Follow `neqsim-compressor-antisurge-recycle` for the JSON
contract, screening-map provenance, commissioning evidence, and the mandatory
`NOT_CERTIFIED_FOR_PROTECTION` boundary.
## Per-Area Three-Phase Flash Control (Speed-Up)
Switch the multiphase (three-phase) flash off on areas that are known to be
two-phase only. On a multi-area plant this is usually the cheapest speed-up
available, because the extra phase-stability analysis otherwise runs on every
flash of every unit of every recycle iteration.
```java
plant.setMultiPhaseCheck(true); // baseline for all areas
plant.setMultiPhaseCheck("Export train A", false); // dry gas: no third phase
compressionTrain.setMultiPhaseCheck(false); // a single ProcessSystem
```
- `ProcessSystem.setMultiPhaseCheck(boolean)` returns the number of distinct
fluids updated; `getMultiPhaseCheck()` returns `TRUE`/`FALSE`/`null` (unset).
- `ProcessModel.setMultiPhaseCheck(String areaName, boolean)` returns `-1` for an
unknown area name — check it, do not assume the call landed.
- The setting is re-applied at the start of each run, so a `ThreePhaseSeparator`
temporarily enabling the check cannot leak three-phase mode into the area.
- Default is unset: fluids keep whatever flag they were built with.
**Only disable it where the absence of a third phase is known from the process,
not assumed.** Free water, an aqueous glycol/MEG phase, or a liquid CO2 phase
will be silently missed. Keep the check ON for inlet separation, produced-water,
glycol/MEG, and CO2-rich areas.
## Per-Area Property-Initialization Level (Speed-Up)
Every `Stream.run()` ends with `initProperties()`, which evaluates mass density,
viscosity, thermal conductivity and diffusivity. Selecting `DENSITY_ONLY` skips
the transport-property correlations and is roughly an order of magnitude cheaper
per stream.
```java
plant.setPropertyInitLevel(Stream.PropertyInitLevel.DENSITY_ONLY); // whole plant
plant.setPropertyInitLevel("Subsea", Stream.PropertyInitLevel.FULL); // one area
compressionTrain.setPropertyInitLevel(Stream.PropertyInitLevel.DENSITY_ONLY);
feedStream.setPropertyInitLevel(Stream.PropertyInitLevel.FULL); // one stream
```
- Same API shape as `setMultiPhaseCheck`: `ProcessSystem.setPropertyInitLevel`
returns the number of streams updated, `ProcessModel.setPropertyInitLevel(area,
level)` returns `-1` for an unknown area, the setting propagates into nested
`ModuleInterface` sub-processes, is applied to units added afterwards, and is
re-applied at the start of every run.
- Default is unset (`null`): each stream keeps `PropertyInitLevel.FULL`.
> **⚠ `DENSITY_ONLY` makes transport properties read back as ZERO, not throw.**
> `getViscosity()`, `getThermalConductivity()` and the diffusion coefficients
> return `0.0`. That silently corrupts pipeline pressure drop, heat-exchanger UA,
> mechanical design, and every flow-assurance calculation. Use it only for
> mass/energy-balance solves, and set the level back to `FULL` (or call
> `getFluid().initProperties()` on the stream) before reading transport
> properties.
Both switches are re-applied by `run(UUID)`, `run_step(UUID)`,
`runSequential(UUID)`, `runParallel(UUID)`, `runHybrid(UUID)`,
`runDataflow(UUID)` and `runTransient(double, UUID)`.
## Required Checks
- Temperatures and pressures use explicit units in setters.
- Fluids have a mixing rule before simulation.
- Branching streams use cloned fluids or well-defined equipment outlet streams.
- Phase-separating equipment exposes conventional gas/liquid product accessors;
domain aliases return those same objects rather than separate streams.
- `getInletStreams()` and `getOutletStreams()` contain every externally connected,
live stream. Their entries remain object-identical across reruns so downstream
equipment never retains a stale product reference.
- After solving a phase separator or column, verify the gas outlet contains a gas
phase, the liquid outlet contains an oil/liquid/aqueous phase, and total plus
per-component balances close. Getter existence alone is not product validation.
- Every equipment item has a unique name inside the process.
- Recycles and adjusters are added after their connected equipment.
- **Pick the separator class by orientation, or set it explicitly.** Gas-capacity
results depend on orientation because a horizontal vessel derates the gas area by
the design liquid level (default 80% → gas area `(1−0.8)=0.2×`, a **5× over-read**
of gas velocity / `getGasLoadFactor()` if used for a vertical vessel):
- `Separator` and `ThreePhaseSeparator` default to **horizontal** — use for the
horizontal 1st/2nd/3rd-stage separators (VA-tag).
- `GasScrubber`, `GasScrubberSimple`, `NeqGasScrubber` (2-phase) and
`ThreePhaseGasScrubber` (3-phase) default to **vertical** — prefer these for
vertical scrubbers (VG-tag); their constructor calls `setOrientation("vertical")`.
- Either way you can override with `separator.setOrientation("vertical"|"horizontal")`.
Verified: with the correct orientation, `getGasLoadFactor()` matches a hand
Souders-Brown `v·sqrt(ρg/(ρl−ρg))`. `setInternalDiameter()` itself propagates
correctly through `run()` — the trap is orientation, not diameter.
- Every suction/export scrubber in a recompression/export-compression train has its
liquid knock-out (`scrubber.getLiquidOutStream()`) closed back to the separator
operating at the matching pressure — never leave it unconnected (it is silently
dropped, under-counting oil/condensate recovery). See `neqsim-platform-modeling`
Section 4 for the seed + TP-setter + `Recycle` pattern.
- **Overall mass balance MUST be verified before accepting any solution.** Sum the mass
flow (`kg/hr`) of all feed streams and all product/export streams; the closure error
must be `< 0.1 %` (`abs(sum_in - sum_out) / sum_in`). A larger imbalance means a stream
was dropped (e.g. an unconnected scrubber liquid), a recycle did not converge, or a
splitter fraction is wrong — fix the flowsheet and re-run; do NOT report results from an
unbalanced model. For multi-area `ProcessModel`s, also confirm `plant.run()` converged.
- Results include the verified mass balance, expected pressure ordering, and physically
reasonable phase splits.
- For industrial engineering use, assess every exact `method@version` with
`EngineeringMethodQualificationRegistry`: require an independent benchmark, approved structured applicability
envelope, intended use, controlled service inputs, uncertainty basis and explicit extrapolation policy. A converged
calculation outside the envelope remains investigation evidence, not a qualified engineering result.
- Use `EngineeringNumericalHealthAnalyzer` to capture convergence, mass/energy closure, residual, and sensitivity
evidence for every process state that governs an engineering decision. Required but absent evidence must remain
`INCOMPLETE`; never replace unavailable closure data with zero.
- Use `Dexpi20XmlWriter` for native Plant/P&ID exchange and `Dexpi20ProcessModelWriter` for native Process/PFD/BFD
exchange. A Proteus document with a changed header is not native DEXPI 2.0. Preserve the conformance report and still
require a named-CAE round-trip before project qualification.
- Use `Cfihos20HandoverExporter` only with an exact project-controlled CFIHOS 2.0 Core or Extended RDL delivery.
Verify its digest from controlled bytes, map canonical nodes/properties/documents to exact RDL identifiers, record
mapping approval, and close the generated gap register. Its CSVs are staging data; Principal transformation,
target-system validation, contractual completeness, and information acceptance remain external decisions.
- Compressor, pump, heat exchanger, separator, and pipeline cases identify applicable
standards through `neqsim-standards-lookup`.
## Related Skills
- `neqsim-api-patterns` — fluid setup, equipment APIs, and result extraction.
- `neqsim-input-validation` — pre-simulation physical bounds and component checks.
- `neqsim-troubleshooting` — flash and process convergence recovery.
- `neqsim-process-extraction` — JSON builder and route extraction from documents.
- `neqsim-notebook-patterns` — executable notebook structure and devtools setup.