taiwan-water-meter-installation · git:20260704.5e814f8 · 2026-07-04 · sha256 c50c9e8f14e421e4
taiwan-water-meter-installation git:20260704.5e814f8A
Immutable. This exact content is served forever at /api/v1/blob/c50c9e8f14e421e4.
--- name: taiwan-water-meter-installation description: "This skill should be used when planning, designing, or reviewing the water meter installation locations, types, and configurations for buildings in Taiwan according to the Taiwan Water Corporation guidelines." --- # Taiwan Water Meter Installation Principles ## Context & Purpose This skill defines the operational parameters and constraints for installing water meters (總表, 分表, 獨立表) in Taiwan, as regulated by the Taiwan Water Corporation (台灣自來水股份有限公司用戶表位設置原則). ## Parameters & Classification | Meter Type | Size (Diameter) | Description | |------------|-----------------|-------------| | Large Meter (大表) | ≧ 50 mm | - | | Small Meter (小表) | ≦ 40 mm | - | | Master Meter (總表) | - | Meter followed by other meters for individual billing. | | Sub Meter (分表) | - | Meter following a master meter. | | Independent Meter (獨立表) | - | Directly supplies user, no subsequent billing meters. | | Smart Meter (智慧表) | - | Part of AMR system, transmits signals to TWC. | ## Location Rules - **General Safety**: Must be in safe spaces allowing easy meter reading, replacement, maintenance, and good drainage. - **Prohibited Areas**: Inside toilets, bathrooms, underground basements (for master/independent meters), or back of the house. Must not obstruct traffic/pedestrians. - **Master/Independent Meters**: - Should be placed within the property line, adjacent to the road building line. - Allowed on open spaces behind arcades, flower beds, green areas, or beside stairways. - Prohibited in driveways or parking spaces. - **Sub Meters (Apartments/Condos)**: - Default location is the **roof** (must have a fixed stairway and railing). - If roof access is impossible, meters can be grouped in a dedicated **Meter Room** on specific floors (NOT in the basement). The room needs a 4-inch floor drain and a 35cm threshold. ## Clearances & Dimensions - **Vertical Clearance**: Meter bottom must be ≧ 2 cm above the ground. - **Recessed Spaces (崁入式表位)**: - Axis to roof/gas meter clearance: ≧ 30 cm - Axis to wall clearance: ≧ 10 cm - For ≦25mm meters: Space ≧ 50(W) x 55(H) x 20(D) cm - For 40mm meters: Space ≧ 70(W) x 65(H) x 22(D) cm ## Execution Logic for AI When checking MEP plans: 1. Verify meter location against prohibited areas (basement, toilets, driveways). 2. Check if sub-meters are placed on the roof. If not, verify the existence of a valid meter room. 3. Validate clear dimensions for recessed meters.